Tezgen TezSafety TSB 90 Type B2 Biosafety Cabinet Class 2 B2
It is a class 2 and B 2 type that provides 100% exhaust.
It provides safety against hazardous particles by protecting personnel, products and the environment while working with substances that meet Biosafety Level 1, 2 or 3 requirements. It is also used in applications related to antineoplastic drugs, genetic materials, asbestos and airborne hazardous particles.
These cabinets have special features designed to meet the unique needs of cell research. Some models come with a modified wing that can accommodate a microscope, while other models have a temperature-controlled work surface to maintain the viability of the cells.
Type B2 Biosafety Cabinets have the same airflow pattern to provide personnel and product protection. These cabinets are designed to be connected to the outside with rigid ducts. During operation, room air is drawn into the top of the cabinet and passes through a supply HEPA filter. Filtered air flows into the work area. In addition, room air is drawn in through the inlet grille located in the access opening in the work area. Contaminated air is completely exhausted through the exhaust HEPA filter and then discharged outside. The filtered exhaust air is 100% discharged outside the laboratory through a special exhaust system and remote blower. • Air flow: %100 Exhaust
• Touch Electronic Control System
• HEPA Filters
• Production in accordance with 12469 Standards
• Touch control panel should have filter life time, UV life time, window opening and closing, fan controls, fan efficiency, condition of front window barriers, all alarms, UV countdown timing, device total operating time, tracking on touch PLC screen
TSB-90 External Dimensions: 1050 x850x 2200 mm Internal Dimensions: 900 x 630 x 625 mm LCD Controls
TSB-120 External Dimensions: 1340x850x 2200 mm Internal Dimensions: 1190 x 630 x 625 mm LCD Controls
TSB-10 External Dimensions: 1640 x850x 2200 mm Internal Dimensions: 1490 x 630 x 625 mm LCD Controls
Internal Dimensions (WxLxH) mm 1190x630x625
External Dimensions (WxLxH) mm 1340x850x1450
Support Leg (WxLxH) mm 1340x850x745
Support Leg Height from Ground 840 mm
Air Flow (m/s) Inlet 0.50 ± %5 Down Flow 0.38 ± %5
HEPA Filter Types (EN 1822)
Main Filter H14 HEPA 0.3 µm %99.995
Exhaust Filter H14 HEPA 0.3 µm %99.995
Pre-Filter (EN779, Optional) EU4
Clean Area Class EN ISO 14644-3 < ISO 5 US FED 209E < Class 100
Exhaust Fan Motor Capacity Suitable for 10 m horizontal and 3 m vertical duct length
* Work Table Standard 304 Stainless Steel (Single piece monoblock or multi-piece with apparatus)
Optional 316L Stainless Steel
Front Glass Opening (mm) Preset/Std 200cm ± 10mm Max 450cm ± 10mm
Noise Level Normal Mode < 56 dB(A) Eco (Standby) Mode < 50 dB(A)
Work Area Lighting (Lux) 750 – 1200 Lux
Front Glass < 6 mm
Power Consumption (kW)
Fan Filter Unit 530 W
Lighting 50 W UV Lamp
30 W Electrical outlet voltage and current 220-240 VAC / 16A Supply Voltage / Frequency / Power / Current 230 VAC / 50 Hz / 3000 W / 16A
Package/Pallet Dimensions (WxHxD) mm 1450x1005x2000
Weight (kg) without support stand 300 kg